Official Title
Objective Evaluation of the Effect of Oculoplastic Operations Using the Vectra M 3D Imaging System
Brief Summary

An objective assessment of that part of the spectrum of ophthalmic eyelid surgeries thatfocuses on correcting the position of entropy (e.g. ectropion, ptosis surgery) is verydifficult - although it is possible to use different measuring parameters (distance ofpupillary reflexes from the edges of the eyelid), comparing different distances on theface, exophthalmometry or the lid laxity test - the so-called snap-back test, but allthese methods are based either on the subjective assessment of the examiner or on thecorrectness of the attached ruler, and their objectivity is therefore very low.

Detailed Description

The goal of the project is to develop a methodology for evaluating the results of
operations using a stereo photographic system, to objectively evaluate the functionality
and results of various eyelid operations, and subsequently to expand the use of the
device in other ophthalmological indications.

Different files will be created where the effect of different operations will be
monitored in parallel.

Lateral canthal hinge surgery will be evaluated in the pilot group, and ptosis surgery
through an anterior approach will be evaluated in the second group.

In all patients, the position of the eyelids, their change before and after surgery, the
periorbital volume, and the relation of the eyelids to the periorbital landscape will be
assessed metrically.

The Vectra M3 device will be used for the measurement.

The expected cohort size is 40 patients in each group.

Recruiting
Eyelid Ptoses
Ectropion Eyelids
Entropion;Eye

Other: Vectra M3 imaging

Study subjects from both arms will undergo Vectra M3 imaging to evaluate the result of
the surgery.

Eligibility Criteria

Inclusion Criteria:

- Eyelid ptosis

- Eyelid entropion

- Eyelid ectropion

Exclusion Criteria:

- Refusal to participate in the study

- Not signing the Informed Consent Form

- Inability/reluctance to cooperate in the study

Eligibility Gender
All
Eligibility Age
Minimum: 4 Years ~ Maximum: N/A
Countries
Czechia
Locations

University Hospital Ostrava
Ostrava, Moravian-Silesian Region, Czechia

Investigator: Jiří Hynčica
Contact: 0042059737
jiri.hyncica@fno.cz

Contacts

Jiří Hynčica
0042059737 - 2587
jiri.hyncica@fno.cz

Adam Kopecký, MD,PhD,FEBO, Principal Investigator
University Hospital Ostrava

University Hospital Ostrava
NCT Number
Keywords
Vectra M3 device
Eyelid Ptoses
stereo photographic system
eyelid surgery
MeSH Terms
Entropion
Ectropion
Blepharoptosis